X-OPT-io
X-OPT-io
Description
Module types
The module X-OPT-io provides 20 electrically isolated (opto-coupler) channels. "i" stands for the number of inputs, "o" stands for the number of outputs.
Inputs
The high speed inputs can cause interrupts and can be read by software. All modules are available in 2 different versions: /L (logic level inputs) or /P (process level inputs).
Outputs
Modules with mark /x provide outputs for 40 V at 90 mA, modules without this mark 70 V at 20 mA.
Watchdog
The module provides an watchdog. If this will not be triggered in time, all outputs will be switched off. Additional the watchdog can cause an interrupt.
Specifications
Parameter | Value | Unit |
Outputs (version /L and /P): | ||
- Number, max. | 20 | - |
- Output voltage, max. | 70 | V |
- Output voltage, max. at log. 0 (Iout = 20 mA) | <0,4 | V |
- Output power, max. per channel | 150 | mW |
Outputs (version /Lx and /Px): | ||
- Number, max. | 20 | - |
- Output voltage, max. | 40 | V |
- Output voltage, max. at log. 0 (Iout = 90 mA) | <0,4 | V |
- Output power, max. per channel | tbd | mW |
Inputs (version /L and /Lx): | ||
- Number, max. | 20 | - |
- Input voltage, max. | +-18 | V |
- Level max., detection of log. 0 | 2,2 | V |
- Level min., detection of log. 1 | 4 | V |
- Input current, typ. | 2 | mA |
Inputs (version /P and /Px): | ||
- Number, max. | 20 | - |
- Input voltage, max. | +-30 | V |
- Level max., detection of log. 0 | 5 | V |
- Level min., detection of log. 1 | 13 | V |
- Input current, typ. | 2 | mA |
Watchdog-Timer, time out period | 200, 1600 | ms |
Operating temperature range | 0 ... +70 | °C |
Dimensions | 29x58x8 | mm |
Weight, min./max. | 8,6/9,35 | g |
Power consumption 3,3V | 325+10*x (x=number of active DOUTs) | mA |